High Temperature (HT) Steam Line Repair

Overview

A weld crack was found in a pump room steam line on an FPSO. This line required an in service repair without the use of hot work, met the design temperature of 1830C, and a defect modelled as a circumferential loss of 5mm was required to meet ABS class approval.

The line had the following specifications:

Structure Steam Line
Surface Preparation Sa 2.5
Class Approval ABS
Design Pressure 970 kPa
Design Temperature 1380C
Application Temperature 500C
Design Life 2 years
Wrap Length 1,000 mm
Pipe Diameter 200 mm NB
Corrosion Type Cracking
Defect Details Circumferential through wall
Post Cure Yes - heat tapes

Solution

  • Technowrap™ 2K HT system with temperature capability up to 220°C
  • Heat tapes used to provided post cure temperature of 60°C - 80°C
  • Crack modelled as complete section loss over weld section
  • Sponge-Jet TM surface preparation used for surface preparation

Benefits

  • Sponge-JetTM fully recyclable system reduced equipment and materials footprint led to improve freight costs
  • Start-up design was used to bring line back on line two days quicker
  • ABS approved repair
  • TechnowrapTM provided both structural loads and pressure containing requirements

ICR.IAS JV 